CSB Investigation Report No. 2019-04-I-PA 2019 Safety Safety Environmental Environmental
Philadelphia Energy Solutions Refinery Air Cooler Rupture
Philadelphia Energy Solutions Refinery, Pennsylvania
Related equipment → Air cooler (air_cooler)
0Fatalities
0Injuries
Corrosive ruptureMechanism code STD
Failure Mode · ISO 14224 Mapping
Damage mechanism (recorded in KB)
Corrosive ruptureSTD
ISO functional code (as recorded)
ISO 14224:2016 functional failure code
STD · Structural failure
ISO STD — Structural failure.
1What Happened

HF alkylation unit air cooler (fin-fan) corroded elbow rupture -> HF leak

2Root Cause

Wet H2S corrosion elbow thinning + inadequate air-cooler bundle inspection

3Reliability Lessons (from investigation root cause)
  • Wet H2S corrosion elbow thinning
  • inadequate air-cooler bundle inspection
4Associated Failure Mechanisms (Keywords)
air cooler fin tube bundle corrosion elbow leak bundle leak
About the Failure-Mode Code (click to expand)

The recorded code STD is an ISO 14224:2016 functional failure code (describes what the equipment failed to do). The damage mechanism (how it failed) is shown in the Mapping block above. The two are distinct dimensions in ISO 14224.

5Evidence Source (transparent)
Authority:U.S. Chemical Safety and Hazard Investigation Board (CSB)
Official Report:www.csb.gov ↗
Data Verification:verified_url_csb_sitemap
Report No. 2019-04-I-PA · Data from CSB public investigation conclusions, compiled by Reliability AI, for reliability demonstration purposes only. This case is derived from public incident investigation reports for learning purposes only. AIM does not endorse or guarantee its accuracy.