宜宾恒达科技'7·12'重大爆炸着火事故(2018,19 死)
宜宾恒达科技有限公司,宜宾市江安县阳春工业园区(四川省应急管理厅发布)
Related equipment → Reactor (reactor)
19Fatalities
12Injuries
ExplosionMechanism code OTH
⌗Failure Mode · ISO 14224 Mapping
Damage mechanism (recorded in KB)
ExplosionOTH
ISO functional code (as recorded)
ISO 14224:2016 functional failure code
OTH · Other
ISO OTH — Other.
1What Happened
库管误将氯酸钠当作丁酰胺入库,操作员误投入 2R301 脱水釜→氯酸钠在升温脱水作业中发生化学爆炸,引发甲苯蒸气二次爆炸及氯酸钠/甲苯/甲醇殉爆
2Root Cause
未批先建违法生产;原料标识不明入库错误;未经核实误投易爆危化品;设计/施工/评价单位违法违规;监管审批把关不严
3Reliability Lessons (from investigation root cause)
- The 'Root Cause' above is the core lesson of this accident; not split further.
4Associated Failure Mechanisms (Keywords)
误投料 氯酸钠 反应釜 化学爆炸 标识错误 丁酰胺 升温脱水 原料管理