← Back to KB navigation
Equipment ADR-101
FM adr_dual_tower_sync_fail
ISO 14224 mode M M
Source engineering_estimate
双塔切换时序紊乱
ADR-101 · Air Dryer (Desiccant)
Related equipment → ADR-101
0.82Source conf.
—Evidence conf.
MISO 14224 mode
1Failure Mechanism
Function:连续干燥
Failure cause:时序控制故障致两塔同时再生或同时工作
Damage mechanism:时序故障致双塔冲突
2Source Basis (where this FM comes from)
engineering_estimate
Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by engineering_estimate.
3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):std:ISO 7183 — Compressed air dryers — Specifications and testing · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
ISO 7183
No separate clause reference.
6Derived Analysis (seeded from this FM)
7/3/5FMEA Sev/Occ/Det
0.03RBI λ
0.75Monitor pdet
6 月Insp. int.
Current tasks:时序逻辑校验
RCFA incident:双塔切换时序紊乱:时序控制故障致两塔同时再生或同时工作,后果类型 Operational,严重度 7
7RCM Maintenance Decision (strategy landing)
PMScheduled (Proactive) Maintenance
Recommended task标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=instrument
Governing standardsGB/T 21109IEC 61511ISA 84
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。