← Back to KB navigation
Equipment E-101
FM tube_hole_enlargement
ISO 14224 mode OTH Other
Source OPC Ontology KB
管孔扩大→胀接松动 (Tube Hole Enlargement)
E-101 · Shell-and-tube heat exchanger
Related equipment → E-101
0.82Source conf.
0.80Evidence conf.
OTHISO 14224 mode
1Failure Mechanism
Function:固定管束两端,隔离管/壳程介质
Failure cause:介质腐蚀;多次胀接;管孔加工精度不足
2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark
Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.
3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.8 · Evidence source:Industry consensus
Governing standards (evidence):ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_9c7fa5bf85974d70ef57d29a0a747f2a7458030677405755 — ITP-4 Shell and Tube Exchangers(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 8 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
API 580API 581-2025GB/T 7826-2012ISO 14224:2016SAE JA1011_202411
Standard clause references (21):
GB/T 7826-2012GB/T 27921-2011GB/T 36894-2018GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 510API 570API 571API 579-1/ASME FFS-1API 754API 576API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
6/6/3FMEA Sev/Occ/Det
0.46RBI λ
0.55Monitor pdet
4 月Insp. int.
Current tasks:超声波测厚检查管孔壁厚 | 检查胀接处密封性 | 必要时重新胀接或堵管
RCFA incident:E-101 发生管孔扩大→胀接松动 (Tube Hole Enlargement),严重程度 6,后果类型 Operational
7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task无损检测(UT/VT/MT/PT), 按 API 581 RBI 风险定级设定检验间隔; 泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=corrosion; seal_leak
Governing standardsAPI 510API 570API 571API 581API 682
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。