FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment H-101 FM stack_corrosion ISO 14224 mode STD Structural deficiency Source OPC Ontology KB
Stack Corrosion
H-101 · fired_heater
Related equipment → H-101
0.82Source conf.
0.70Evidence conf.
STDISO 14224 mode
1Failure Mechanism

Function:排放烟气至大气

Failure cause:燃料含硫量高,烟气露点温度高;烟囱保温不良导致壁温低于酸露点;运行中频繁启停,产生冷凝液

Damage mechanism:烟囱酸露点腐蚀(stack acid corrosion)+ 频繁启停冷凝

2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.7 · Evidence source:engineering_estimate
Governing standards (evidence):
  • std:API-571 — API 571 — Damage Mechanisms Affecting Fixed Equipment · 损伤机理归类框架
  • std:API-570 — API 570 — Piping Inspection Code · 工艺管道检验
  • std:NBIC-NB23 — NBIC NB-23 — National Board Inspection Code · 国家锅炉压力容器检验规范
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 3 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 571API 580API 581-2025GB/T 7826-2012ISO 14224:2016SAE JA1011_202411

Standard clause references (22):

GB/T 7826-2012GB/T 27921-2011GB/T 36894-2018GB/T 44958-2024GB/T 37243-2019GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 510API 570API 571API 579-1/ASME FFS-1API 754API 576API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
8/6/3FMEA Sev/Occ/Det
0.46RBI λ
0.8Monitor pdet
4 月Insp. int.

Current tasks:定期测厚检查烟囱壁厚 | 检查内衬腐蚀情况 | 监测烟气露点温度

RCFA incident:H-101 发生烟囱腐蚀 (Stack Corrosion),严重程度 8,后果类型 Safety/Environmental

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task温度/红外热成像监测, 超温报警与根因排查; 无损检测(UT/VT/MT/PT), 按 API 581 RBI 风险定级设定检验间隔
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=corrosion; overheat
Governing standards
API 530API 570API 571API 581厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM stack_corrosion · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.