Positioner Failure
K-201A · Centrifugal compressor
Related equipment → K-201A
0.75Source conf.
0.70Evidence conf.
OTHISO 14224 mode
1Failure Mechanism
Function:接近喘振线时快速开启回流,增加流量
Failure cause:反馈杆松动或磨损;电路板故障;气路喷嘴堵塞
2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark
Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.
3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.7 · Evidence source:OEM_manual
Governing standards (evidence):ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_4baf3822af099542c2a396ec6e994d6b7479345845137275 — 压缩机防喘振系统完整技术方案ima://7479345845137275/pdf_11035ae55c1b08ddb9e6d8bfbece61fe_09ac5889eb7d93d00ced858558ecc00c7479345845137275 — 空气压缩机RCM维护方案ima://7479345845137275/pdf_11035ae55c1b08ddb9e6d8bfbece61fe_cb149c9742b85d0a68be7323645916837479345845137275 — 空气压缩机FMEA分析报告
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411
Standard clause references (16):
GB/T 7826-2012GB/T 27921-2011GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 571API 754API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
6/6/2FMEA Sev/Occ/Det
0.4RBI λ
0.55Monitor pdet
4 月Insp. int.
Current tasks:每6个月进行定位器自诊断测试 | 每季度清洁气源过滤器,检查反馈杆
RCFA incident:K-201A 发生定位器故障,严重程度 6,后果类型 Safety
7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task按压差/效率监测设定清洗周期 + 过滤/防堵维护; 标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=fouling; instrument
Governing standardsAPI 571GB/T 21109IEC 61511ISA 84厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.