← Back to KB navigation
Equipment M-201A
FM fm_34
ISO 14224 mode ELP External leakage - process
Source OPC Ontology KB
Piping Leak -> Insufficient Vacuum
M-201A · MVR unit (mechanical vapor recompression)
Related equipment → M-201A
0.75Source conf.
0.65Evidence conf.
ELPISO 14224 mode
1Failure Mechanism
Function:连接各设备至真空泵
Failure cause:腐蚀性介质;机械振动;安装缺陷
2Source Basis (where this FM comes from)
OPC Ontology KBChina Emergency MgmtQuant benchmark
Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·China Emergency Mgmt·Quant benchmark.
3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.65 · Evidence source:engineering_estimate
Governing standards (evidence):ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_c34878de0ef99baefb229cbae10a3b8b7458030677405755 — ITP-9 Skidded Equipment(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411
Standard clause references (17):
GB/T 7826-2012GB/T 27921-2011GB/T 36894-2018GB/T 44958-2024GB/T 37243-2019GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 754API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
8/2/3FMEA Sev/Occ/Det
0.22RBI λ
0.55Monitor pdet
4 月Insp. int.
Current tasks:每日监测真空度趋势 | 每月进行肥皂泡检漏 | 每季度进行超声波检漏 | 建立SIL评估(按IEC 61511)确定安全完整性等级 | 每1个月执行proof test验证保护层有效性
RCFA incident:M-201A 发生管线泄漏→真空度不足,严重程度 8,后果类型 Safety
7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task无损检测(UT/VT/MT/PT), 按 API 581 RBI 风险定级设定检验间隔; 振动频谱分析 + 动平衡 + 激光对中, 状态监测趋势管理; 泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=corrosion; seal_leak; vibration
Governing standardsAPI 510API 570API 571API 581API 670API 682API 684ISO 10816
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。