FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment M-201A FM fm_39 ISO 14224 mode OTH Other Source OPC Ontology KB
Loose Wiring / Terminals
M-201A · MVR unit (mechanical vapor recompression)
Related equipment → M-201A
0.75Source conf.
0.65Evidence conf.
OTHISO 14224 mode
1Failure Mechanism

Function:温度/压力/液位/流量/振动/电导率

Failure cause:安装时未按规定扭矩紧固;长期振动导致螺母自松;温度变化引起热胀冷缩差异

2Source Basis (where this FM comes from)
OPC Ontology KBChina Emergency MgmtQuant benchmark

Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·China Emergency Mgmt·Quant benchmark.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.65 · Evidence source:OEM_manual
Governing standards (evidence):
  • ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_c34878de0ef99baefb229cbae10a3b8b7458030677405755 — ITP-9 Skidded Equipment(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411

Standard clause references (17):

GB/T 7826-2012GB/T 27921-2011GB/T 36894-2018GB/T 44958-2024GB/T 37243-2019GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 754API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
6/6/2FMEA Sev/Occ/Det
0.4RBI λ
0.8Monitor pdet
4 月Insp. int.

Current tasks:每6个月检查并紧固所有接线端子 | 使用扭矩扳手按规范力矩紧固 | 红外热成像检测异常温升

RCFA incident:M-201A 发生接线松动,严重程度 6,后果类型 Operational

7RCM Maintenance Decision (strategy landing)
RTFDesign Modification / Inspection Task
Recommended task温度/红外热成像监测, 超温报警与根因排查; 振动频谱分析 + 动平衡 + 激光对中, 状态监测趋势管理; 防静电/惰化/接地设计整改 + 环境控制(RTF)
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=overheat; static; vibration
Governing standards
API 530API 670API 684GB 50058IEC 60079ISO 10816NFPA 77厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM fm_39 · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.