FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment P-101A FM seizure_galling ISO 14224 mode LOO Low output Source OPC Ontology KB
卡涩/咬死 (Seizure/Galling)
P-101A · Centrifugal pump
Related equipment → P-101A
0.75Source conf.
0.75Evidence conf.
LOOISO 14224 mode
1Failure Mechanism

Function:减少叶轮出口→入口的回流泄漏,维持容积效率

Failure cause:间隙过小;润滑失效;异物进入

2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBNUREG (US NRC)Quant benchmark

Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·NUREG (US NRC)·Quant benchmark.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.75 · Evidence source:OEM_manual
Governing standards (evidence):
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_283b5a73620a2a66736f9bc2640d5c2a7479345845137275 — 离心泵结构原理及常见故障原因分析
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_8a1d60fcb81b5086bdefbc680fe61bd57479345845137275 — 离心泵叶轮常见故障分析及避免策略
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_9b8c77c034c4d40cd470345085c90c9c7479345845137275 — 装置离心泵振动九大杀手排查
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_e433bfbdf4a9a4b807fc752c6d3e429d7479345845137275 — 离心泵运行中常见的八类隐形杀手及对策
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_d8bc091028963fe6986a324f751866257479345845137275 — 机械密封维护检修规程
  • ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_b8e3f40c0cbcc204999d1c296cc7b2467458030677405755 — ITP-7 Pumps(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 6 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 580GB/T 11348GB/T 6075GB/T 7826-2012ISO 13372ISO 13374ISO 14224:2016ISO 17359SAE JA1011_202411

Standard clause references (16):

GB/T 7826-2012GB/T 27921-2011GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 571API 754API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
9/3/4FMEA Sev/Occ/Det
0.28RBI λ
0.8Monitor pdet
12 月Insp. int.

Current tasks:监测温度和振动 | 检查配合面润滑 | 避免干运转

RCFA incident:P-101A 发生卡涩/咬死 (Seizure/Galling),严重程度 9,后果类型 Safety/Environmental

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task温度/红外热成像监测, 超温报警与根因排查; 振动频谱分析 + 动平衡 + 激光对中, 状态监测趋势管理; 泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=overheat; seal_leak; vibration
Governing standards
API 510API 530API 670API 682API 684ISO 10816厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM seizure_galling · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.