电蚀 (Electrical Erosion)
P-102A · Centrifugal pump
Related equipment → P-102A
0.75Source conf.
0.80Evidence conf.
OTHISO 14224 mode
1Failure Mechanism

Function:支撑径向+部分轴向载荷

Failure cause:电机轴电流未有效接地;变频器产生高频共模电压;轴承绝缘设计不足

2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBNUREG (US NRC)Quant benchmark

Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·NUREG (US NRC)·Quant benchmark.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.8 · Evidence source:Industry consensus
Governing standards (evidence):
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_283b5a73620a2a66736f9bc2640d5c2a7479345845137275 — 离心泵结构原理及常见故障原因分析
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_8a1d60fcb81b5086bdefbc680fe61bd57479345845137275 — 离心泵叶轮常见故障分析及避免策略
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_9b8c77c034c4d40cd470345085c90c9c7479345845137275 — 装置离心泵振动九大杀手排查
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_e433bfbdf4a9a4b807fc752c6d3e429d7479345845137275 — 离心泵运行中常见的八类隐形杀手及对策
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_d8bc091028963fe6986a324f751866257479345845137275 — 机械密封维护检修规程
  • ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_b8e3f40c0cbcc204999d1c296cc7b2467458030677405755 — ITP-7 Pumps(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 6 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 580GB/T 11348GB/T 6075GB/T 7826-2012ISO 13372ISO 13374ISO 14224:2016ISO 17359SAE JA1011_202411

Standard clause references (16):

GB/T 7826-2012GB/T 27921-2011GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 571API 754API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
7/2/3FMEA Sev/Occ/Det
0.22RBI λ
0.8Monitor pdet
4 月Insp. int.

Current tasks:检查接地碳刷 | 测量轴电压 | 监测轴承振动

RCFA incident:P-102A 发生电蚀 (Electrical Erosion),严重程度 7,后果类型 Safety

7RCM Maintenance Decision (strategy landing)
RTFDesign Modification / Inspection Task
Recommended task壁厚/型线超声测厚 + 耐磨层状态检查, 视情修复或涂层; 绝缘/电气试验 + 继电保护定值校核 + 操动机构特性测试; 防静电/惰化/接地设计整改 + 环境控制(RTF); 标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=electrical; erosion; instrument; static
Governing standards
API 510API 570API 581GB 50058GB/T 14285GB/T 21109IEC 60034IEC 60079IEC 61511IEEE C57ISA 84NFPA 77
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.