← Back to KB navigation
Equipment R-201A
FM set_point_drift
ISO 14224 mode FTS Fail to start on demand
Source OPC Ontology KB
起跳值偏移 (Set Point Drift)
R-201A · Reactor
Related equipment → R-201A
0.75Source conf.
0.65Evidence conf.
FTSISO 14224 mode
1Failure Mechanism
Function:超压时自动开启泄压
Failure cause:弹簧蠕变;阀座结垢;长期未校验
2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark
Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.
3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.65 · Evidence source:engineering_estimate
Governing standards (evidence):ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_9d8b149bd2f3be727c6d967efbf962997458030677405755 — ITP-2 Pressure Vessels(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 10 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411
Standard clause references (22):
GB/T 7826-2012GB/T 27921-2011GB/T 36894-2018GB/T 44958-2024GB/T 37243-2019GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 510API 570API 571API 579-1/ASME FFS-1API 754API 576API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
7/6/4FMEA Sev/Occ/Det
0.46RBI λ
0.8Monitor pdet
4 月Insp. int.
Current tasks:定期校验安全阀整定压力 | 检查弹簧状态 | 清洁阀座
RCFA incident:R-201A 发生起跳值偏移 (Set Point Drift),严重程度 7,后果类型 Safety
7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task蠕变测量/金相监测, 按剩余寿命管理; 无损检测(UT/MT/PT) 监测裂纹萌生, 关键转动件定时拆检; 无损检测(UT/VT/MT/PT), 按 API 581 RBI 风险定级设定检验间隔; 按压差/效率监测设定清洗周期 + 过滤/防堵维护
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=corrosion; creep; fatigue; fouling
Governing standardsAPI 530API 570API 571API 579API 581API 612ASME IIIASME VIII厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。