← Back to KB navigation
Equipment SC-101
FM intercooler_fouling
ISO 14224 mode Screw intercooler fouling Screw intercooler fouling
Source synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)
中间冷却器结垢
SC-101 · Screw Compressor
Related equipment → SC-101
0.82Source conf.
—Evidence conf.
Screw intercooler foulingISO 14224 mode
1Failure Mechanism
Function:冷却级间气体
Failure cause:冷却水结垢/污堵
Damage mechanism:冷却器换热下降,排气温度上升(API 619 冷却器)
2Source Basis (where this FM comes from)
synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)
Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类).
3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):std:API 617 — Axial and Centrifugal Compressors · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 3 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
API 619API 617ISO 14224:2016GB/T 6075ISO 13372API 580API 571GB/T 7826-2012SAE JA1011_202411
No separate clause reference.
6Derived Analysis (seeded from this FM)
4/4/4FMEA Sev/Occ/Det
0.28RBI λ
0.8Monitor pdet
6 月Insp. int.
Current tasks:端差监测 | 化学清洗
RCFA incident:中间冷却器结垢:冷却水结垢/污堵,后果类型 Operational,严重度 4
7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task按压差/效率监测设定清洗周期 + 过滤/防堵维护; 温度/红外热成像监测, 超温报警与根因排查
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=fouling; overheat
Governing standardsAPI 530API 571厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。