FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment V-101 FM fm_6 ISO 14224 mode LOO Low output Source OPC Ontology KB
Valve Blockage / Internal Leak
V-101 · Filter separator
Related equipment → V-101
0.82Source conf.
0.65Evidence conf.
LOOISO 14224 mode
1Failure Mechanism

Function:实现设备功能

Failure cause:介质含杂质或结垢;阀门长期未清洗;阀座密封面磨损

2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.65 · Evidence source:engineering_estimate
Governing standards (evidence):
  • ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_9d8b149bd2f3be727c6d967efbf962997458030677405755 — ITP-2 Pressure Vessels(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 2 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411

Standard clause references (20):

GB/T 7826-2012GB/T 27921-2011GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 510API 570API 571API 579-1/ASME FFS-1API 754API 576API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
6/4/4FMEA Sev/Occ/Det
0.34RBI λ
0.55Monitor pdet
4 月Insp. int.

Current tasks:每周检查阀门开关是否顺畅 | 每日监测差压或流量异常 | 每月进行排污检查

RCFA incident:V-101 发生阀门堵塞/内漏,严重程度 6,后果类型 Operational

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task按压差/效率监测设定清洗周期 + 过滤/防堵维护; 标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理; 泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=fouling; instrument; seal_leak
Governing standards
API 510API 571API 682GB/T 21109IEC 61511ISA 84厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM fm_6 · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.