Operational Operational
1992 聚合反应失控(反应器+搅拌密封 O 环吹出释放)
Maleic co-polymer plant, UK (HSE Sragtech Case)
Related equipment → Reactor (reactor)Related equipment → Control valve (control_valve)Related equipment → Agitator (Agitator)
0Fatalities
0Injuries
OverpressureMechanism code OTH
⌗Failure Mode · ISO 14224 Mapping
Damage mechanism (recorded in KB)
OverpressureOTH
ISO functional code (as recorded)
ISO 14224:2016 functional failure code
OTH · Other
ISO OTH — Other.
1What Happened
苯乙烯经开启的切断阀返流至单体线,次日批次反应远超预期→反应器超压,35psig 安全阀起跳但 50psig 爆破片未破,搅拌器密封 O 环吹出释放工艺蒸气
2Root Cause
反应器泄放系统不能处理共聚放热;搅拌密封压力低于爆破片;无快速淬水;误操作使物料返流通过失效止回阀
3Reliability Lessons (from investigation root cause)
- The 'Root Cause' above is the core lesson of this accident; not split further.
4Associated Failure Mechanisms (Keywords)
聚合 反应失控 反应器 返流 止回阀 搅拌密封 超压 安全阀 爆破片