FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment AGI-101 FM agi_impeller_imbalance ISO 14224 mode M M Source engineering_estimate
叶轮不平衡/磨损
AGI-101 · Agitator
Related equipment → AGI-101
0.82Source conf.
Evidence conf.
MISO 14224 mode
1Failure Mechanism

Function:实现混合/传质

Failure cause:叶轮结垢/磨损/腐蚀致不平衡与振动升高

Damage mechanism:叶轮结垢/磨损致不平衡

2Source Basis (where this FM comes from)
engineering_estimate

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by engineering_estimate.

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • std:ISO 21940 — Mechanical vibration — Rotor balancing · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
ISO 21940

No separate clause reference.

6Derived Analysis (seeded from this FM)
6/4/5FMEA Sev/Occ/Det
0.05RBI λ
0.75Monitor pdet
6 月Insp. int.

Current tasks:动平衡校验 | 叶轮检查

RCFA incident:叶轮不平衡/磨损:叶轮结垢/磨损/腐蚀致不平衡与振动升高,后果类型 Operational,严重度 6

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task按压差/效率监测设定清洗周期 + 过滤/防堵维护; 无损检测(UT/VT/MT/PT), 按 API 581 RBI 风险定级设定检验间隔; 振动频谱分析 + 动平衡 + 激光对中, 状态监测趋势管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=corrosion; fouling; vibration
Governing standards
API 570API 571API 581API 670API 684ISO 10816厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM agi_impeller_imbalance · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.