FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment AGI-101 FM agi_mech_seal_leak ISO 14224 mode M M Source engineering_estimate
Mechanical Seal Leak
AGI-101 · Agitator
Related equipment → AGI-101
0.82Source conf.
Evidence conf.
MISO 14224 mode
1Failure Mechanism

Function:轴封隔离工艺介质

Failure cause:密封面磨损/弹簧失效致工艺介质外泄

Damage mechanism:密封面磨损/弹簧失效致介质外泄

2Source Basis (where this FM comes from)
engineering_estimate

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by engineering_estimate.

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • std:API 682 — Pumps — Shaft Sealing Systems for Centrifugal and Rotary Pumps · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 682

No separate clause reference.

6Derived Analysis (seeded from this FM)
9/4/4FMEA Sev/Occ/Det
0.06RBI λ
0.8Monitor pdet
6 月Insp. int.

Current tasks:密封冲洗检查 | 泄漏监测

RCFA incident:机械密封泄漏:密封面磨损/弹簧失效致工艺介质外泄,后果类型 Safety/Environmental,严重度 9

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=seal_leak
Governing standards
API 510API 682
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM agi_mech_seal_leak · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.