FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment AGI-101 FM agi_vibration_high ISO 14224 mode M M Source engineering_estimate
振动高(底座松动/不对中)
AGI-101 · Agitator
Related equipment → AGI-101
0.82Source conf.
Evidence conf.
MISO 14224 mode
1Failure Mechanism

Function:稳定运行

Failure cause:地脚螺栓松动/不对中致整机振动超标

Damage mechanism:地脚松动/不对中致振动超标

2Source Basis (where this FM comes from)
engineering_estimate

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by engineering_estimate.

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • std:ISO 10816 — Mechanical vibration — Evaluation of machine vibration by measurements on non-rotating parts · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
ISO 10816

No separate clause reference.

6Derived Analysis (seeded from this FM)
6/3/5FMEA Sev/Occ/Det
0.05RBI λ
0.8Monitor pdet
6 月Insp. int.

Current tasks:振动监测 | 紧固检查

RCFA incident:振动高(底座松动/不对中):地脚螺栓松动/不对中致整机振动超标,后果类型 Operational,严重度 6

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task振动频谱分析 + 动平衡 + 激光对中, 状态监测趋势管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=vibration
Governing standards
API 670API 684ISO 10816
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM agi_vibration_high · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.