Equipment C-101 FM fm ISO 14224 mode STD Structural deficiency Source OPC Ontology KB
Impeller Corrosion / Stress Corrosion
C-101 · Centrifugal compressor
Related equipment → C-101
0.82Source conf.
0.80Evidence conf.
STDISO 14224 mode
1Failure Mechanism

Function:旋转加速气体,提供离心力提升压力

Failure cause:介质含腐蚀性成分;材料选择不当;残余拉应力

2Source Basis (where this FM comes from)
OPC Ontology KBQuant benchmarkCSB Accident DB

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·Quant benchmark·CSB Accident DB.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.8 · Evidence source:Industry consensus
Governing standards (evidence):
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_4baf3822af099542c2a396ec6e994d6b7479345845137275 — 压缩机防喘振系统完整技术方案
  • ima://7479345845137275/pdf_11035ae55c1b08ddb9e6d8bfbece61fe_09ac5889eb7d93d00ced858558ecc00c7479345845137275 — 空气压缩机RCM维护方案
  • ima://7479345845137275/pdf_11035ae55c1b08ddb9e6d8bfbece61fe_cb149c9742b85d0a68be7323645916837479345845137275 — 空气压缩机FMEA分析报告
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411

Standard clause references (16):

GB/T 7826-2012GB/T 27921-2011GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 571API 754API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
8/5/3FMEA Sev/Occ/Det
0.4RBI λ
0.55Monitor pdet
4 月Insp. int.

Current tasks:每6个月进行目视检查和着色探伤 | 每2年进行介质成分分析

RCFA incident:C-101 发生叶轮腐蚀/应力腐蚀,严重程度 8,后果类型 Safety/Environmental

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task无损检测(UT/VT/MT/PT), 按 API 581 RBI 风险定级设定检验间隔
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=corrosion
Governing standards
API 570API 571API 581
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM fm · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.