Duplex Filter Changeover Failure
C-101 · Centrifugal compressor
Related equipment → C-101
0.75Source conf.
0.70Evidence conf.
OTHISO 14224 mode
1Failure Mechanism

Function:提供过滤+冷却+加压润滑油给轴承和齿轮

Failure cause:切换阀长期未操作导致卡涩;润滑油中杂质沉积在阀芯;密封件老化或损坏

2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark

Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.7 · Evidence source:OEM_manual
Governing standards (evidence):
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_4baf3822af099542c2a396ec6e994d6b7479345845137275 — 压缩机防喘振系统完整技术方案
  • ima://7479345845137275/pdf_11035ae55c1b08ddb9e6d8bfbece61fe_09ac5889eb7d93d00ced858558ecc00c7479345845137275 — 空气压缩机RCM维护方案
  • ima://7479345845137275/pdf_11035ae55c1b08ddb9e6d8bfbece61fe_cb149c9742b85d0a68be7323645916837479345845137275 — 空气压缩机FMEA分析报告
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411

Standard clause references (16):

GB/T 7826-2012GB/T 27921-2011GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 571API 754API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
6/5/4FMEA Sev/Occ/Det
0.34RBI λ
0.55Monitor pdet
4 月Insp. int.

Current tasks:每3个月进行一次切换阀操作测试,确保灵活转动 | 每次切换时记录操作力矩,若超过基准值20%则拆检清洗

RCFA incident:C-101 发生双联过滤器切换失效,严重程度 6,后果类型 Safety

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task按压差/效率监测设定清洗周期 + 过滤/防堵维护; 温度/红外热成像监测, 超温报警与根因排查; 泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=fouling; overheat; seal_leak
Governing standards
API 510API 530API 571API 682厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。