← Back to KB navigation
Equipment E-201A
FM fm_4
ISO 14224 mode VIB Vibration
Source OPC Ontology KB
Baffle Vibration Fatigue
E-201A · Shell-and-tube heat exchanger
Related equipment → E-201A
0.75Source conf.
0.70Evidence conf.
VIBISO 14224 mode
1Failure Mechanism
Function:引导壳程流体横向冲刷管束,增强传热同时支撑管子
Failure cause:壳程流体流速过高或脉动;折流板间距过大或厚度不足;管束与折流板间隙过大导致冲击
2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark
Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.
3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.7 · Evidence source:engineering_estimate
Governing standards (evidence):ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_9c7fa5bf85974d70ef57d29a0a747f2a7458030677405755 — ITP-4 Shell and Tube Exchangers(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 8 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411
Standard clause references (21):
GB/T 7826-2012GB/T 27921-2011GB/T 36894-2018GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 510API 570API 571API 579-1/ASME FFS-1API 754API 576API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
7/4/3FMEA Sev/Occ/Det
0.34RBI λ
0.8Monitor pdet
4 月Insp. int.
Current tasks:每3个月进行振动监测,安装加速度传感器 | 当振动幅值超过阈值时,调整流速或增加支撑
RCFA incident:E-201A 发生折流板振动疲劳,严重程度 7,后果类型 Operational
7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task无损检测(UT/MT/PT) 监测裂纹萌生, 关键转动件定时拆检; 振动频谱分析 + 动平衡 + 激光对中, 状态监测趋势管理; 标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=fatigue; instrument; vibration
Governing standardsAPI 579API 612API 670API 684ASME VIIIGB/T 21109IEC 61511ISA 84ISO 10816
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。