FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment GB-101 FM housing_crack ISO 14224 mode Housing crack Housing crack Source synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)
箱体裂纹
GB-101 · Gearbox (Speed Reducer/Increaser)
Related equipment → GB-101
0.82Source conf.
Evidence conf.
Housing crackISO 14224 mode
1Failure Mechanism

Function:包容齿轮与轴承

Failure cause:铸造缺陷或过载冲击

Damage mechanism:箱体在应力集中处萌生裂纹扩展(API 677 壳体强度)

2Source Basis (where this FM comes from)
synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类).

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • std:API 677 — General-purpose Gear Units · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 2 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 677ISO 6336AGMA 2001ISO 14224:2016GB/T 3480GB/T 6075ISO 13372API 580GB/T 7826-2012SAE JA1011_202411

No separate clause reference.

6Derived Analysis (seeded from this FM)
7/2/3FMEA Sev/Occ/Det
0.06RBI λ
0.8Monitor pdet
6 月Insp. int.

Current tasks:磁粉/渗透检测 | 应变监测

RCFA incident:箱体裂纹:铸造缺陷或过载冲击,后果类型 Operational/Safety,严重度 7

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task状态监测/定期检查, 按趋势与阈值管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=(无显式机理信号, 由 current_tasks 推导)
Governing standards
API 581厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。