FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment INS-101 FM solenoid_valve_coil_burn ISO 14224 mode Solenoid coil burn Solenoid coil burn Source synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)
电磁阀线圈烧毁
INS-101 · Instrumentation & Safety Instrumented System (SIS)
Related equipment → INS-101
0.82Source conf.
Evidence conf.
Solenoid coil burnISO 14224 mode
1Failure Mechanism

Function:控制气路换向

Failure cause:过热/电压异常

Damage mechanism:电磁阀线圈烧毁致 SIS 无法驱动(IEC 61511 执行机构)

2Source Basis (where this FM comes from)
synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类).

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • std:IEC 61511 — Functional safety—Safety instrumented systems · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 1 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
IEC 61511GB/T 21109GB/T 20438IEC 61508ISA 84.00.01ISO 14224:2016API 580GB/T 7826-2012SAE JA1011_202411GB/T 27921-2023

No separate clause reference.

6Derived Analysis (seeded from this FM)
7/2/3FMEA Sev/Occ/Det
0.08RBI λ
0.8Monitor pdet
6 月Insp. int.

Current tasks:线圈温度监测 | 冗余电磁阀

RCFA incident:电磁阀线圈烧毁:过热/电压异常,后果类型 Safety,严重度 7

7RCM Maintenance Decision (strategy landing)
PMScheduled (Proactive) Maintenance
Recommended task绝缘/电气试验 + 继电保护定值校核 + 操动机构特性测试; 温度/红外热成像监测, 超温报警与根因排查; 标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=electrical; instrument; overheat
Governing standards
API 530GB/T 14285GB/T 21109IEC 60034IEC 61511IEEE C57ISA 84厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM solenoid_valve_coil_burn · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.