FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment MVR-01 FM EVAP-C3-FM1 ISO 14224 mode SYN SYN Source Synthetic
分布不均→干壁过热
MVR-01 · Mechanical Vapor Recompression (MVR) System
Related equipment → MVR-01
0.65Source conf.
Evidence conf.
SYNISO 14224 mode
1Failure Mechanism

Function:均匀布液

Failure cause:分布器设计、液位失控

Damage mechanism:干壁/局部过热 (Dry-wall / Local Overheating)

2Source Basis (where this FM comes from)
Synthetic

Source confidence 0.65: this FM is derived from the ontology KB and cross-validated by Synthetic.

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_c34878de0ef99baefb229cbae10a3b8b7458030677405755 — ITP-9 Skidded Equipment(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 5 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
GB/T 7826-2012API 660

No separate clause reference.

6Derived Analysis (seeded from this FM)
6/5/5FMEA Sev/Occ/Det
0.25RBI λ
Monitor pdet
12 月Insp. int.

Current tasks:布液均匀性检查 + 液位联锁校验 + 壁温监测(热电偶) + 分布器喷嘴通堵检查

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task温度/红外热成像监测, 超温报警与根因排查
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=overheat
Governing standards
API 530厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM EVAP-C3-FM1 · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.