FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment MVR-01 FM FPH-C5-FM1 ISO 14224 mode SYN SYN Source Synthetic
阀门内漏/卡涩
MVR-01 · Mechanical Vapor Recompression (MVR) System
Related equipment → MVR-01
0.65Source conf.
Evidence conf.
SYNISO 14224 mode
1Failure Mechanism

Function:液位控制

Failure cause:结垢/磨损

Damage mechanism:阀门内漏/磨损 (Valve Leakage / Wear)

2Source Basis (where this FM comes from)
Synthetic

Source confidence 0.65: this FM is derived from the ontology KB and cross-validated by Synthetic.

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_c34878de0ef99baefb229cbae10a3b8b7458030677405755 — ITP-9 Skidded Equipment(杜邦制造质量检验测试计划)
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 2 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
GB/T 7826-2012API 550

No separate clause reference.

6Derived Analysis (seeded from this FM)
5/4/4FMEA Sev/Occ/Det
0.2RBI λ
Monitor pdet
12 月Insp. int.

Current tasks:阀门内漏(声波/压差)检测 + 行程/力矩校验 + 阀座/阀芯检查 + 结垢清理

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task按压差/效率监测设定清洗周期 + 过滤/防堵维护; 标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理; 泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=fouling; instrument; seal_leak
Governing standards
API 510API 571API 682GB/T 21109IEC 61511ISA 84厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM FPH-C5-FM1 · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.