Equipment PSV-101 FM inlet_line_blockage ISO 14224 mode PSV inlet blockage PSV inlet blockage Source synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)
入口管线堵塞
PSV-101 · Pressure Safety Valve (Relief Device)
Related equipment → PSV-101
0.82Source conf.
Evidence conf.
PSV inlet blockageISO 14224 mode
1Failure Mechanism

Function:导压至阀口

Failure cause:结垢/冻结/异物

Damage mechanism:入口压降过大致颤振或延迟起跳(API 520 入口压降≤3%)

2Source Basis (where this FM comes from)
synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类)

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by synthetic + standards-based engineering estimate (ISO 14224 / API / IEC 61511 框架归类).

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • std:API 520 — Sizing, Selection, and Installation of Pressure-relieving Devices · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 3 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 520API 521API 526API 510API 570API 574ASME VIIIGB/T 20801API 581ISO 14224:2016API 580GB/T 7826-2012SAE JA1011_202411

No separate clause reference.

6Derived Analysis (seeded from this FM)
6/2/3FMEA Sev/Occ/Det
0.08RBI λ
0.7Monitor pdet
6 月Insp. int.

Current tasks:入口压降监测 | 管线吹扫

RCFA incident:入口管线堵塞:结垢/冻结/异物,后果类型 Safety,严重度 6

7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task按压差/效率监测设定清洗周期 + 过滤/防堵维护
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=fouling
Governing standards
API 571厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM inlet_line_blockage · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.