FM Traceability Card · trace the source basis (tap links to trace back)
← Back to KB navigation
Equipment VFD-101 FM cooling_fan_failure ISO 14224 mode Cooling fan failure Cooling fan failure Source synthetic + standards-based engineering estimate (ISO 14224 / IEC 61800 / IEEE C57 框架归类)
冷却风扇失效
VFD-101 · Variable Frequency Drive (VFD)
Related equipment → VFD-101
0.82Source conf.
Evidence conf.
Cooling fan failureISO 14224 mode
1Failure Mechanism

Function:强制风冷,带走 IGBT 与整流桥损耗

Failure cause:风扇轴承卡滞或绕组开路,风冷流量不足

Damage mechanism:冷却风扇轴承磨损卡滞或电机绕组开路,强制风冷流量不足致 IGBT 结温上升

2Source Basis (where this FM comes from)
synthetic + standards-based engineering estimate (ISO 14224 / IEC 61800 / IEEE C57 框架归类)

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by synthetic + standards-based engineering estimate (ISO 14224 / IEC 61800 / IEEE C57 框架归类).

3Evidence Chain (supporting basis)
This FM has no offline curated evidence text; it is derived from the ontology KB and cross-validated by the listed standard clauses and related accident investigations.
Governing standards (evidence):
  • std:IEC 61800-5-1 — Adjustable speed electrical power drive systems — Safety requirements · 机理级工程估计,非实测;引用 governing standard 作为分类出处
  • std:IEEE 841 — IEEE Standard for Petroleum and Chemical Industry—Severe Duty TEFC Motors · 机理级工程估计,非实测;引用 governing standard 作为分类出处
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 3 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
IEC 61800-5-1IEEE 841

No separate clause reference.

6Derived Analysis (seeded from this FM)
6/4/4FMEA Sev/Occ/Det
0.12RBI λ
0.85Monitor pdet
6 月Insp. int.

Current tasks:风扇转速/风压监测 | 定期润滑/更换

RCFA incident:冷却风扇失效:风扇轴承卡滞或绕组开路,风冷流量不足,后果类型 Operational,严重度 6

7RCM Maintenance Decision (strategy landing)
PMScheduled (Proactive) Maintenance
Recommended task绝缘/电气试验 + 继电保护定值校核 + 操动机构特性测试; 温度/红外热成像监测, 超温报警与根因排查
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=electrical; overheat
Governing standards
API 530GB/T 14285IEC 60034IEEE C57厂家规范
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。
FM cooling_fan_failure · Data from OPC KB and whitelisted public sources, compiled by Reliability AI for reliability demonstration only. Evidence ref codes are internal indices, not public DOIs.