Accident Lesson Card · Real investigation (tap external link for official report)
← Back to KB navigation
CSB Investigation Report No. 2006-08-I-IL 2006 Safety Safety
Universal Form Clamp Open-Tank Flammable Vapor Cloud Explosion (Bellwood)
Universal Form Clamp Co., Bellwood, Illinois
Related equipment → Storage tank (storage_tank)
1Fatalities
5Injuries
ExplosionMechanism code ELP
Failure Mode · ISO 14224 Mapping
Damage mechanism (recorded in KB)
ExplosionELP
ISO functional code (as recorded)
ISO 14224:2016 functional failure code
ELP · External leakage - process
ISO ELP — External leakage - process.
1What Happened

Open-top tank: mixing/heating flammable liquid generated vapor cloud, ignited

2Root Cause

Mixing/heating flammable liquid in open-top tank without adequate safety controls; vapor cloud ignited — 1 killed, 5 injured

3Reliability Lessons (from investigation root cause)
  • The 'Root Cause' above is the core lesson of this accident; not split further.
4Associated Failure Mechanisms (Keywords)
storage tank open top tank flammable liquid vapor cloud ignition explosion mixing heating
About the Failure-Mode Code (click to expand)

The recorded code ELP is an ISO 14224:2016 functional failure code (describes what the equipment failed to do). The damage mechanism (how it failed) is shown in the Mapping block above. The two are distinct dimensions in ISO 14224.

5Evidence Source (transparent)
Authority:U.S. Chemical Safety and Hazard Investigation Board (CSB)
Official Report:www.csb.gov ↗
Data Verification:verified_url_csb_sitemap
Report No. 2006-08-I-IL · Data from CSB public investigation conclusions, compiled by Reliability AI, for reliability demonstration purposes only. This case is derived from public incident investigation reports for learning purposes only. AIM does not endorse or guarantee its accuracy.