氮气供应中断 (N2 Supply Loss)
V-201A · Storage tank
Related equipment → V-201A
0.75Source conf.
0.65Evidence conf.
OTHISO 14224 mode
1Failure Mechanism
Function:维持罐顶微正压氮气保护
Failure cause:氮气瓶或管网压力不足;管道破裂或接头泄漏;阀门误操作或故障
2Source Basis (where this FM comes from)
OPC Ontology KBCSB Accident DBQuant benchmark
Source confidence 0.75: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·CSB Accident DB·Quant benchmark.
3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.65 · Evidence source:engineering_estimate
Governing standards (evidence):ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_a261222a8a070345158934949919a5e37458030677405755 — ITP-6 Tanks - Shop Fabricated(杜邦制造质量检验测试计划)ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_ef31c26853319b4b471659463e26846d7458030677405755 — APPENDIX A7-1 Tanks MIQA Inspection Template
4Related Real Accidents (traceable to accident cards)
This FM is recorded in 16 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.
5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411
Standard clause references (22):
GB/T 7826-2012GB/T 27921-2011GB/T 36894-2018GB/T 44958-2024GB/T 37243-2019GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 510API 653API 571API 579-1/ASME FFS-1API 754API 576API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
9/2/3FMEA Sev/Occ/Det
0.22RBI λ
0.8Monitor pdet
4 月Insp. int.
Current tasks:安装氮气压力低报警 | 配置备用氮气源 | 定期检查管道和阀门
RCFA incident:V-201A 发生氮气供应中断 (N2 Supply Loss),严重程度 9,后果类型 Safety
7RCM Maintenance Decision (strategy landing)
CBMOn-Condition Maintenance
Recommended task标定/零点-跨度校验 + SIL Proof test + 阀门行程试验 + 变更管理; 泄漏监测 + 密封/填料定期更换, 螺栓热紧固
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=instrument; seal_leak
Governing standardsAPI 510API 682GB/T 21109IEC 61511ISA 84
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.