Hickson & Welch 间歇蒸馏釜清垢着火(1992,重大火无死亡)
Hickson & Welch Ltd, Castleford, UK (HSE Sragtech Case)
Related equipment → Distillation column (distillation_column)Related equipment → Agitator (Agitator)
0Fatalities
0Injuries
FailureMechanism code OTH
⌗Failure Mode · ISO 14224 Mapping
Damage mechanism (recorded in KB)
FailureOTH
ISO functional code (as recorded)
ISO 14224:2016 functional failure code
OTH · Other
ISO OTH — Other.
1What Happened
30 年未清的间歇蒸馏釜残垢被误判为稳定焦油,蒸汽加热软化后金属耙搅动→可燃蒸气引燃、喷射火损毁控制楼
2Root Cause
首次清釜无分析残垢/大气;未发 PTW for raking;未隔离进口;金属耙用于易燃蒸气区;温度测量位置差
3Reliability Lessons (from investigation root cause)
- The 'Root Cause' above is the core lesson of this accident; not split further.
4Associated Failure Mechanisms (Keywords)
蒸馏 残垢 焦油 清釜 自燃 蒸汽加热 金属工具 喷射火 盲板隔离