Equipment CV-201A FM fm_10 ISO 14224 mode LOO Low output Source OPC Ontology KB
Valve Plug Sticking -> Failure to Actuate
CV-201A · Control valve
Related equipment → CV-201A
0.82Source conf.
0.70Evidence conf.
LOOISO 14224 mode
1Failure Mechanism

Function:实现设备功能

Failure cause:气源含杂质或水分;长期未动作导致锈蚀;润滑剂干涸或变质

2Source Basis (where this FM comes from)
OPC Ontology KBQuant benchmarkCSB Accident DBNUREG (US NRC)hse

Source confidence 0.82: this FM is derived from the ontology KB and cross-validated by OPC Ontology KB·Quant benchmark·CSB Accident DB·NUREG (US NRC)·hse.

3Evidence Chain (supporting basis)
Evidence text:None
Evidence conf.:0.7 · Evidence source:OEM_manual
Governing standards (evidence):
  • ima://7479345845137275/wechatarticle_11035ae55c1b08ddb9e6d8bfbece61fe_71e0997a12b0754a71091e1cbcccab197479345845137275 — 20种阀门常见故障速查(内漏/卡涩/开度异常)
  • ima://7458030677405755/word_11035ae55c1b08ddb9e6d8bfbece61fe_c791ba6bfe6ad927c9b48502742d33147458030677405755 — APPENDIX A8-2 Functionally Critical Valves(杜邦MIQA工具)
4Related Real Accidents (traceable to accident cards)

This FM is recorded in 8 real accident investigation(s); tap the report no. to open the corresponding accident lesson card.

5Applicable Standards & Clauses
API 580GB/T 7826-2012ISO 14224:2016SAE JA1011_202411

Standard clause references (17):

GB/T 7826-2012GB/T 27921-2011GB/T 44958-2024GB/T 4888-2008GB/T 29639-2020AQ/T 3034-2022API 581API 580API 570API 754API 576API 689API 755ISO 14224:2016ISO 20815:2018IEC 61511:2016ISO 31000:2018
6Derived Analysis (seeded from this FM)
8/4/4FMEA Sev/Occ/Det
0.34RBI λ
0.55Monitor pdet
4 月Insp. int.

Current tasks:每周进行电磁阀动作测试 | 每日检查气源过滤质量 | 每月监测电磁阀动作时间

RCFA incident:CV-201A 发生阀芯卡涩→不动作,严重程度 8,后果类型 Operational

7RCM Maintenance Decision (strategy landing)
PMScheduled (Proactive) Maintenance
Recommended task功能测试/标定/校验, 按厂家与 SIL 要求周期执行
Suggested intervalHigh risk 1-3 mo / Medium 6-12 mo / Low risk at turnaround (by API 581 RBI risk ranking)
Decision basis机理类别=(无显式机理信号, 由 current_tasks 推导)
Governing standards
IEC 61511ISA 84
⚠ This decision is engineering-inferred by RCM logic from the damage mechanism / root cause / failure cause — it is not derived from measured site history. Confirm with the equipment owner and process before execution.
⚠ 本卡技术正文(功能 / 致因 / 损伤机理 / RCFA 叙事)保留中文原文——依可信 AI 红线,自由技术文本不自动机翻、不编造英文译文。UI、设备类型、FM 名、ISO 码、标准号均为英文。